Karl Fischer Moisture Titrator (Coulometric titration) MKC-710S

Karl Fischer Moisture Titrator (Coulometric titration) MKC-710S

Large color TFT-LCD with a touch panel (8.4-inch) enables easy key entry Reduction of power consumption by 30% compared with the conventional product

Deskripsi

Features

  • Fast measurements
  • Our proprietary technology achieves electrolytic speeds up to 2.6mg H2O/min.
    This shortens the time required for pre-titrations and sample measurements considerably.
    Karl Fischer Moisture Titrator (Coulometric titration)
MKC-710S

  • Replaceable diaphragm
  • Easy maintenance when measuring samples which tend to contaminate the diaphragm as eg. oils: Thanks to a unique mechanism, the ceramic diaphragm of the optional titration cell unit (12-03635-01) can be replaced.
    Karl Fischer Moisture Titrator (Coulometric titration)
MKC-710S

  • Result output as PDF files
  • Paper saving and environmentally friendly – results no longer need to be printed.
    Measurement results are converted to PDF and can be stored in a USB flash drive.
    Karl Fischer Moisture Titrator (Coulometric titration)
MKC-710S

  • The MKC-710S contains functions to support compliance with the following:
  • ・European Pharmacopoeia Chapter 2.5.32. WATER: MICRO DETERMINATION: VERIFICATION OF ACCURACY
    ・Japanese Pharmacopoeia Eighteenth Edition Chapter 2.48: Water determination (Karl Fischer Method):
     2.4 Suitability of determination

  • Large color TFT-LCD with a touch panel (8.4-inch)
  • Two different user levels and permissions
  • With a unique mechanism , the ceramic diaphragm of the optional titration cell unit can be replaced
  • Measurement results are converted to PDF and can be stored in a USB flash drive
  • By reviewing the conventional electrolytic control method , reduction of power consumption by 30%
  • When using ADP-611 , a patented scan mode automatically determines the optimal evaporation temperature. (Japanese Patent No. 4247093)
  • Manual solvent change unit is included
    • Specifications

  • Type : Karl Fischer Moisture Titrator
  • Model : MKC-710S
  • Standard configuration : MCU-710S+MKC-710+IDP-100+Manual Solvent Change unit
  • Measuring method : Karl Fischer Coulometric titration
  • Measuring range :
      Water content : 1ug to 300mg (depends on reagent)
    • Bromine index : 8ug to 300mg
  • Measurement cell : 2-Component or 1-Component
  • Precision : Relative standard deviation : less than 0.3% (n=10)
  • *Per KEM standard measurement conditions and standard liquids

  • Display resolution : 0.1ug
  • Control method : Constant current pulse time control
  • Endpoint detection : Alternate current polarization method with a twin platinum electrode
  • EP sense method : Selective drift stability or limit measurement time
  • Required solvent :
    • 2-Component cell : Anolyte 100mL , Catholyte 5mL
      1-Component cell : Anolyte 150mL
  • Method : 120
  • Key operation : Touch panel
  • Displays :
    • 1. 8.4-inch color LCD 800 x 600 dots
      2. English / Japanese / Mandarin Chinese / Korean / Russian / Spanish / German / French
      3. 1-channel display
  • Calculation : Concentration of water content , statistics data processing (mean , SD and RSD) and automatic averaging of blank value and factor value
  • Data storage : 500 samples
  • GLP conformance :
    • Registration of operator / User group administration
      Check performance with standard substance : Reminder of scheduled check date / Record of check results
      Reagent life control : Reminder of expiration/Reminder reagent replacement date
      Management of conduction time : Display of operating time
  • External I/O :
    • RS-232C port x4 : for Dot matrix printer , Electronic balance , Data Capture Software (SOFT-CAP) , Evaporator , Multiple sample changer
      USB ×1 : for USB flash drive , Thermal printer , A4 printer , Keyboard , Barcode reader , Foot switch , USB HUB
  • Extensibility : Evaporator ADP-611, Multiple sample changer : CHK-501
  • Ambient condition : Temperature : 5 to 35°C, Humidity : 85%RH or below (no condensation)
  • Power source : AC100 to 240V +/- 10% 50/60 Hz
  • Power consumption : Main unit : Approx. 30W Printer : Approx. 7W
  • Dimensions :
    • Touch-on panel controller : 225(W) x 190(D) x 42(H) mm
      Titration unit : 141(W) x 292(D) x 244(H) mm
      Stirrer : 107(W) x 206(D) x 340(H) mm (not incl. Solvent Change unit)
      Solvent Change Unit : 240(W) x 140(D) x 405(H) mm (not incl. tubing)
      Printer : 106(W) x 180(D) x 88(H) mm
  • Weight : Touch-on panel controller : Approx.1.5kg Titration unit : Approx.3.0kg Stirrer : Approx.2.0kg Solvent Change Unit : Approx.0.6kg Printer : Approx.0.4kg
  • Conformity standard : CE marking EMC : EN61326-1 LVD : EN61010-1
  • Karl Fischer Moisture Titrator (Coulometric titration) MKC-710S
    Karl Fischer Moisture Titrator (Coulometric titration) MKC-710S
    Scroll to top